Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Oncol ; 8: 294, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30175071

RESUMO

Radiomics leverages existing image datasets to provide non-visible data extraction via image post-processing, with the aim of identifying prognostic, and predictive imaging features at a sub-region of interest level. However, the application of radiomics is hampered by several challenges such as lack of image acquisition/analysis method standardization, impeding generalizability. As of yet, radiomics remains intriguing, but not clinically validated. We aimed to test the feasibility of a non-custom-constructed platform for disseminating existing large, standardized databases across institutions for promoting radiomics studies. Hence, University of Texas MD Anderson Cancer Center organized two public radiomics challenges in head and neck radiation oncology domain. This was done in conjunction with MICCAI 2016 satellite symposium using Kaggle-in-Class, a machine-learning and predictive analytics platform. We drew on clinical data matched to radiomics data derived from diagnostic contrast-enhanced computed tomography (CECT) images in a dataset of 315 patients with oropharyngeal cancer. Contestants were tasked to develop models for (i) classifying patients according to their human papillomavirus status, or (ii) predicting local tumor recurrence, following radiotherapy. Data were split into training, and test sets. Seventeen teams from various professional domains participated in one or both of the challenges. This review paper was based on the contestants' feedback; provided by 8 contestants only (47%). Six contestants (75%) incorporated extracted radiomics features into their predictive model building, either alone (n = 5; 62.5%), as was the case with the winner of the "HPV" challenge, or in conjunction with matched clinical attributes (n = 2; 25%). Only 23% of contestants, notably, including the winner of the "local recurrence" challenge, built their model relying solely on clinical data. In addition to the value of the integration of machine learning into clinical decision-making, our experience sheds light on challenges in sharing and directing existing datasets toward clinical applications of radiomics, including hyper-dimensionality of the clinical/imaging data attributes. Our experience may help guide researchers to create a framework for sharing and reuse of already published data that we believe will ultimately accelerate the pace of clinical applications of radiomics; both in challenge or clinical settings.

2.
J Appl Clin Med Phys ; 18(4): 116-122, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28585732

RESUMO

To investigate the inter- and intra-fraction motion associated with the use of a low-cost tape immobilization technique as an alternative to thermoplastic immobilization masks for whole-brain treatments. The results of this study may be of interest to clinical staff with severely limited resources (e.g., in low-income countries) and also when treating patients who cannot tolerate standard immobilization masks. Setup reproducibility of eight healthy volunteers was assessed for two different immobilization techniques. (a) One strip of tape was placed across the volunteer's forehead and attached to the sides of the treatment table. (b) A second strip was added to the first, under the chin, and secured to the table above the volunteer's head. After initial positioning, anterior and lateral photographs were acquired. Volunteers were positioned five times with each technique to allow calculation of inter-fraction reproducibility measurements. To estimate intra-fraction reproducibility, 5-minute anterior and lateral videos were taken for each technique per volunteer. An in-house software was used to analyze the photos and videos to assess setup reproducibility. The maximum intra-fraction displacement for all volunteers was 2.8 mm. Intra-fraction motion increased with time on table. The maximum inter-fraction range of positions for all volunteers was 5.4 mm. The magnitude of inter-fraction and intra-fraction motion found using the "1-strip" and "2-strip" tape immobilization techniques was comparable to motion restrictions provided by a thermoplastic mask for whole-brain radiotherapy. The results suggest that tape-based immobilization techniques represent an economical and useful alternative to the thermoplastic mask.


Assuntos
Análise Custo-Benefício , Irradiação Craniana , Cabeça , Imobilização/instrumentação , Voluntários Saudáveis , Humanos , Imobilização/métodos , Máscaras , Reprodutibilidade dos Testes
3.
Comput Med Imaging Graph ; 48: 1-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26745258

RESUMO

PURPOSE: To assess the uncertainty of quantitative imaging features extracted from contrast-enhanced computed tomography (CT) scans of lung cancer patients in terms of the dependency on the time after contrast injection and the feature reproducibility between scans. METHODS: Eight patients underwent contrast-enhanced CT scans of lung tumors on two sessions 2-7 days apart. Each session included 6 CT scans of the same anatomy taken every 15s, starting 50s after contrast injection. Image features based on intensity histogram, co-occurrence matrix, neighborhood gray-tone difference matrix, run-length matrix, and geometric shape were extracted from the tumor for each scan. Spearman's correlation was used to examine the dependency of features on the time after contrast injection, with values over 0.50 considered time-dependent. Concordance correlation coefficients were calculated to examine the reproducibility of each feature between times of scans after contrast injection and between scanning sessions, with values greater than 0.90 considered reproducible. RESULTS: The features were found to have little dependency on the time between the contrast injection and the CT scan. Most features were reproducible between times of scans after contrast injection and between scanning sessions. Some features were more reproducible when they were extracted from a CT scan performed at a longer time after contrast injection. CONCLUSION: The quantitative imaging features tested here are mostly reproducible and show little dependency on the time after contrast injection.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Imageamento Tridimensional/métodos , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
4.
Med Phys ; 42(3): 1341-53, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25735289

RESUMO

PURPOSE: Radiomics, which is the high-throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (IBEX), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. METHODS: The IBEX software package was developed using the MATLAB and c/c++ programming languages. The software architecture deploys the modern model-view-controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, IBEX is self-contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, IBEX provides an integrated development environment on top of MATLAB and c/c++, so users are not limited to its built-in functions. In the IBEX developer studio, users can plug in, debug, and test new algorithms, extending IBEX's functionality. IBEX also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm-related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the IBEX workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. RESULTS: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the IBEX software to be intuitive, powerful, and easy to use. IBEX can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand-alone IBEX and IBEX's source code can be downloaded. CONCLUSIONS: The authors successfully implemented IBEX, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.


Assuntos
Comportamento Cooperativo , Processamento de Imagem Assistida por Computador/métodos , Software , Algoritmos , Humanos , Modelos Teóricos , Tomografia por Emissão de Pósitrons , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...